Sign In | Join Free | My xpandrally.com
China Shenzhen Inomax Technology Co., Ltd. logo
Shenzhen Inomax Technology Co., Ltd.
Verified Supplier

2 Years

Home > Variable Frequency Drive >

Inomax ACS880 VFD with Profibus Profinet Ethercat Support

Shenzhen Inomax Technology Co., Ltd.
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now

Inomax ACS880 VFD with Profibus Profinet Ethercat Support

Place of Origin : China

Brand Name : INOMAX

Model Number : ACS880

MOQ : 1

Price : $99

Network : NFC

Type : DC/DC Converters

Output Type : Single Phase

Output Current : LOAD

Output Frequency : 50HZ or 60HZ

Size : 505*205*165 mm

Weight : 10KG

Input Voltage : Customizable

Output Voltage : Customizable

Socket Type : Customizable

Communication Protocols : Profibus, Profinet, Ethercat, Ethernet

Motor Compatibility : PMSM Motor

Control Method : Direct Torque Control

Switching Frequency : 10 - 30 microseconds

Insulation Voltage : 800V for 200V class, 1600V for 400V class

Contact Now

Top Fashion Atv340 Multiple Functions Acs880 Acs580 Powerflex 525 Vfd Inverter Atv61

Inomax ACS880 VFD with Profibus Profinet Ethercat Support

Inomax ACS880 VFD with Profibus Profinet Ethercat Support

Products Description

Inomax ACS880 VFD with Profibus Profinet Ethercat Support
Inomax ACS880 VFD with Profibus Profinet Ethercat Support
Inomax ACS880 VFD with Profibus Profinet Ethercat Support
Inomax ACS880 VFD with Profibus Profinet Ethercat Support
Inomax ACS880 VFD with Profibus Profinet Ethercat Support
Inomax ACS880 VFD with Profibus Profinet Ethercat Support
Technical instructions

Inomax ACS880 VFD with Profibus Profinet Ethercat Support
Inomax ACS880 VFD with Profibus Profinet Ethercat Support
Inomax ACS880 VFD with Profibus Profinet Ethercat Support
Inomax ACS880 VFD with Profibus Profinet Ethercat Support
Applications

Inomax ACS880 VFD with Profibus Profinet Ethercat Support
Inomax ACS880 VFD with Profibus Profinet Ethercat Support
Inomax ACS880 VFD with Profibus Profinet Ethercat Support
Inomax ACS880 VFD with Profibus Profinet Ethercat Support
Company Profile

Inomax ACS880 VFD with Profibus Profinet Ethercat Support
Production line

Inomax ACS880 VFD with Profibus Profinet Ethercat Support
Our certificates

Inomax ACS880 VFD with Profibus Profinet Ethercat Support
Product packaging

Inomax ACS880 VFD with Profibus Profinet Ethercat Support
Inomax ACS880 VFD with Profibus Profinet Ethercat Support
FAQ

What is direct torque control?

Semi-Automatic PET Bottle Blowing Machine Bottle Making Machine Bottle Moulding Machine PET Bottle Making Machine is suitable for producing PET plastic containers and bottles in all shapes.

What is the benefit of direct torque control?

* Torque and flux can be changed very fast by changing the references
* High efficiency & low losses - switching losses are minimized because the transistors are switched only when it is needed to keep torque and flux within their hysteresis bands
* The step response has no overshoot
* No dynamic coordinate transforms are needed, all calculations are done in stationary coordinate system
* No separate modulator is needed, the hysteresis control defines the switch control signals directly
* There are no PI current controllers. Thus no tuning of the control is required
* The switching frequency of the transistors is not constant. However, by controlling the width of the tolerance bands the
average switching frequency can be kept roughly at its reference value. This also keeps the current and torque ripple small.Thus the torque and current ripple are of the same magnitude as with vector controlled drives with the same switching frequency.
* Due to the hysteresis control the switching process is random by nature. Thus there are no peaks in the current spectrum. This further means that the audible noise of the machine is low
* The intermediate DC circuit's voltage variation is automatically taken into account in the algorithm (in voltage integration).Thus no problems exist due to dc voltage ripple (aliasing) or dc voltage transients
* Synchronization to rotating machine is straightforward due to the fast control; Just make the torque reference zero and start the inverter. The flux will be identified by the first current pulse
* Digital control equipment has to be very fast in order to be able to prevent the flux and torque from deviating far from the
tolerance bands. Typically the control algorithm has to be performed with 10 - 30 microseconds or shorter intervals. However, the amount of calculations required is small due to the simplicity of the algorithm
* The current measuring devices have to be high quality ones without noise because spikes in the measured signals easily cause erroneous control actions. Further complication is that no low-pass filtering can be used to remove noise because filtering causes delays in the resulting actual values that ruins the hysteresis control
* The stator voltage measurements should have as low offset error as possible in order to keep the flux estimation error down. For this reason the stator voltages are usually estimated from the measured DC intermediate circuit voltage and the transistor control signals
* In higher speeds the method is not sensitive to any motor parameters. However, at low speeds the error in stator resistance used in stator flux estimation becomes critical

What Type Of Motor Is Compatible With Inverters?

Inverter motor type must be a three phase AC induction motor. Preferably, you should use an inverter-grade motor that has 800V insulation for 200V class inverters, or 1600V insulation for 400V class inverters. For motor size, in practice it is much better to find the right size motor for your application; then look for an inverter to match the motor.

What Are Some Of The Common Reasons Why Motors Fail?

The EPRI Power Industry Study by General Electric in 1985 offered the following causes based on 6,000 utility motor failures: 41% were bearing related, 37% were stator related, 10% were rotor related and 12% were other causes.

How do you select a VFD?

The EPRI Power Industry Study by General Electric in 1985 offered the following causes based on 6,000 utility motor failures: 41% were bearing related, 37% were stator related, 10% were rotor related and 12% were other causes.
Contact Us

Inomax ACS880 VFD with Profibus Profinet Ethercat Support

Product Tags:

Inomax ACS880 VFD with Profibus support

      

Variable frequency drive with Profinet

      

Ethercat compatible VFD drive

      
Wholesale Inomax ACS880 VFD with Profibus Profinet Ethercat Support from china suppliers

Inomax ACS880 VFD with Profibus Profinet Ethercat Support Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Shenzhen Inomax Technology Co., Ltd.
*Subject:
*Message:
Characters Remaining: (0/3000)